{"id":2045,"date":"2015-08-18T07:45:05","date_gmt":"2015-08-18T07:45:05","guid":{"rendered":"http:\/\/claitec.com\/?p=2045"},"modified":"2017-02-07T11:38:13","modified_gmt":"2017-02-07T11:38:13","slug":"how-to-make-sure-that-the-tag-works-properly","status":"publish","type":"post","link":"https:\/\/claitec.com\/en\/how-to-make-sure-that-the-tag-works-properly\/","title":{"rendered":"How to make sure that the t-10 tag works properly"},"content":{"rendered":"<p>By checking the tags on the AV-50 antenna, we are able to verify that each person\u2019s T-10 tag is in perfect working condition before entering the protected area.<\/p>\n<p><a href=\"https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Asegurar-funcionamiento-t-10.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2038\" src=\"https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Asegurar-funcionamiento-t-10.jpg\" alt=\"Asegurar funcionamiento t-10\" width=\"1024\" height=\"510\" srcset=\"https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Asegurar-funcionamiento-t-10.jpg 1024w, https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Asegurar-funcionamiento-t-10-300x149.jpg 300w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/p>\n<p><strong>1. Verification register Software.<\/strong><\/p>\n<p><strong>2. AV-50 Antenna (LF antennas and HF included)<\/strong><\/p>\n<p><strong>3. Personnel with Tag.<\/strong><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>As the Tag approaches the verification antenna 4 things happen:<\/p>\n<p>&nbsp;<\/p>\n<p><strong>1. It checks the condition of the tag\u2019s battery.<\/strong><\/p>\n<p>The T-10 Tag communicates the state of charge (voltage) of the battery to the antenna\u2019s verification system.<\/p>\n<p>If the value is below 2.90V the AV-50 antenna shows a red light and beeps to alert the person that the battery\u2019s tag is running out.<\/p>\n<p>&nbsp;<\/p>\n<p>When a battery below 2.90V is detected for the first time or if it is at a 30% charge, the tag has sufficient autonomy to operate under normal conditions and fully functionally for 3 days.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>2. It checks the LF communication.<\/strong><\/p>\n<p>The verification system of the AV-50 antenna emits a detection field.<\/p>\n<p>When a tag is close to the antenna, it awakens, it checks the charge of the battery and it informs the AV-50.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>3. It checks the HF communication.<\/strong><\/p>\n<p>The AV-50 antenna receives the voltage of the battery through the HF. The AV-50 checks the battery\u2019s condition and it makes a decision according to the state of the tag &#8211; if it has sufficient charge, nothing occurs, but if the battery needs replacing, it raises an alarm.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>4. It records the result of the analysis.<\/strong><\/p>\n<p>During each battery analysis and software usage, the system registers the result of the analysis.<br \/>\nBy registering date and time, you can keep track of whether the T-10 tags are properly verified and whether there is a tag that needs to have its battery replaced.<\/p>\n<p>&nbsp;<\/p>\n<p>The following are some Questions and Answer to consider if the test unit lights up in red:<\/p>\n<ul>\n<li><em>How is it determined or measured when the light must be red ?<\/em><\/li>\n<\/ul>\n<p>Measuring the voltage of the battery and determining it is below 2.90V<\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><em>Is a tag with red light still detectable and thus safe to use?<\/em><\/li>\n<\/ul>\n<p>Yes it is, the tag is fully functional even when the battery is low. Because there is a 30% safe battery.<\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li><em>If so, for how long?<\/em><\/li>\n<\/ul>\n<p>For at least 3 days in normal working conditions.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>The AV-50 verification antenna ensures that the T10 Tag works 100% correctly and the battery lasts at least 3 days from verification.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>By checking the tags on the AV-50 antenna, we are able to verify that each person\u2019s T-10 tag is in perfect working condition before entering the protected area. 1. Verification register Software. 2. AV-50 Antenna (LF antennas and HF included) 3. Personnel with Tag. &nbsp; &nbsp; As the Tag approaches the verification antenna 4 things happen: &nbsp; 1. It checks the condition of the tag\u2019s battery. The T-10 Tag communicates the state of charge (voltage) of the battery to the antenna\u2019s verification system. If the value is below 2.90V the AV-50 antenna shows a red light and beeps to alert the person that the battery\u2019s tag is running out. &nbsp; When a battery below 2.90V is detected for the first time or if it is at a 30% charge, the tag has sufficient autonomy to operate under normal conditions and fully functionally for 3 days. &nbsp; 2. It checks the LF communication. The verification system of the AV-50 antenna emits a detection field. When a tag is close to the antenna, it awakens, it checks the charge of the battery and it informs the AV-50. &nbsp; 3. It checks the HF communication. The AV-50 antenna receives the voltage of the [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":2182,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[15],"tags":[],"class_list":["post-2045","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"_links":{"self":[{"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/posts\/2045","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/comments?post=2045"}],"version-history":[{"count":4,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/posts\/2045\/revisions"}],"predecessor-version":[{"id":2049,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/posts\/2045\/revisions\/2049"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/media\/2182"}],"wp:attachment":[{"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/media?parent=2045"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/categories?post=2045"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/tags?post=2045"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}