{"id":2063,"date":"2015-08-20T14:40:08","date_gmt":"2015-08-20T14:40:08","guid":{"rendered":"http:\/\/claitec.com\/como-se-asegura-que-el-campo-de-deteccion-esta-funcionando-correctamente-2\/"},"modified":"2017-02-07T11:37:44","modified_gmt":"2017-02-07T11:37:44","slug":"ensuring-full-working-order-of-the-pas-field-detection-system","status":"publish","type":"post","link":"https:\/\/claitec.com\/en\/ensuring-full-working-order-of-the-pas-field-detection-system\/","title":{"rendered":"Ensuring full working order of the pas\u2019 field detection system"},"content":{"rendered":"<p>The Test-TAG ensures that the PAS system is in full working order.<\/p>\n<p>The PAS\u2019 Test-Tag is a device that is installed within the detection zone of the forklift truck.<\/p>\n<p><a href=\"https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Campo-deteccion-correcto-claitec.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2072\" src=\"https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Campo-deteccion-correcto-claitec.jpg\" alt=\"Campo deteccion correcto claitec\" width=\"1024\" height=\"275\" srcset=\"https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Campo-deteccion-correcto-claitec.jpg 1024w, https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Campo-deteccion-correcto-claitec-300x81.jpg 300w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/p>\n<p>1. Test-Tag, TT50<\/p>\n<p>2.\u00a0Field Activator AC-50 (Antennas LF y HF included)<\/p>\n<p>3. Detection Zone<\/p>\n<p>4. Pedestrian wearing a personal T10 Tag.<\/p>\n<p>&nbsp;<\/p>\n<p>When the sensing field is fine, the <strong>Test-Tag (1)<\/strong> receives and sends a signal to the Activator through High Frequency UHF radio waves and it records its proper functioning.<\/p>\n<p>If the sensing field decreases or stops, the <strong>Test-Tag (1)<\/strong> stops receiving the trigger signal and it sends a warning signal UHF alerting that the field is not being detected.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Campo-deteccion-alarma-claitec.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2060\" src=\"https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Campo-deteccion-alarma-claitec.jpg\" alt=\"Campo deteccion alarma claitec\" width=\"1024\" height=\"347\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>The Cyclically Activator signal expects the <strong>Test-Tag (1)<\/strong> to detect the signal and when it does not arrive, the activator fails and raises the truck\u2019s alarm.<\/p>\n<p><strong>The test-tag acts as a guard<\/strong> who is continually monitoring the field of detection and alerting users in case of failure.<\/p>\n<p>When the message of the test-tag reaches the activator not only does it verify that the field is correct but it also confirms that the communication at 2.4 GHz is in functioning order.<\/p>\n<p><strong>Increasing the security alarm signal in the\u00a0PAS<\/strong><\/p>\n<p>It is possible to achieve a <strong>redundancy detection output out of PAS<\/strong> thanks to the AC-50 activator\u2019s two relays with potential free contact. Both are activated when a person\u2019s tag is detected in the safety zone.<\/p>\n<p>Using these two relays in series we can achieve fault tolerance, redundancy thanks to the series\u2019 circuit.<\/p>\n<p>In the event that one of the two relays fails and stays on, the system will remain in safe mode. If the alarm signal fails a fault should occur in both relays.<\/p>\n<p><a href=\"https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Activador-claitec-rele.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-2058\" src=\"https:\/\/claitec.com\/wp-content\/uploads\/2015\/08\/Activador-claitec-rele.jpg\" alt=\"Activador claitec rele\" width=\"753\" height=\"500\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>If the aim is to achieve greater security, it is recommended to add an external safety relay type SCHNEIDER ELECTRIC \/ TELEMECANIQUE XPSAC5121, however for standard PAS use in forklift trucks, this is totally unnecessary.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Test-TAG ensures that the PAS system is in full working order. The PAS\u2019 Test-Tag is a device that is installed within the detection zone of the forklift truck. 1. Test-Tag, TT50 2.\u00a0Field Activator AC-50 (Antennas LF y HF included) 3. Detection Zone 4. Pedestrian wearing a personal T10 Tag. &nbsp; When the sensing field is fine, the Test-Tag (1) receives and sends a signal to the Activator through High Frequency UHF radio waves and it records its proper functioning. If the sensing field decreases or stops, the Test-Tag (1) stops receiving the trigger signal and it sends a warning signal UHF alerting that the field is not being detected. &nbsp; &nbsp; The Cyclically Activator signal expects the Test-Tag (1) to detect the signal and when it does not arrive, the activator fails and raises the truck\u2019s alarm. The test-tag acts as a guard who is continually monitoring the field of detection and alerting users in case of failure. When the message of the test-tag reaches the activator not only does it verify that the field is correct but it also confirms that the communication at 2.4 GHz is in functioning order. Increasing the security alarm signal in the\u00a0PAS It [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":2181,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[15],"tags":[],"class_list":["post-2063","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"_links":{"self":[{"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/posts\/2063","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/comments?post=2063"}],"version-history":[{"count":3,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/posts\/2063\/revisions"}],"predecessor-version":[{"id":2085,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/posts\/2063\/revisions\/2085"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/media\/2181"}],"wp:attachment":[{"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/media?parent=2063"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/categories?post=2063"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/claitec.com\/en\/wp-json\/wp\/v2\/tags?post=2063"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}